Eco-Friendly, High-Performance Solution for Critical Applications:

  • Halogen-Free:RoHS compliant, environmentally safe, and reduces harmful emissions.
  • High-Temperature Resistance:-40¡ãC to +105¡ãC, ideal for demanding conditions.
  • UL Certified:Meets global safety standards for reliable, secure use.
  • Durable & Long-Lasting:Outstanding abrasion and corrosion resistance for extended product life.

 

Perfect For:

  • Industrial Equipment
  • Automotive & Electrical Systems
  • Appliances & OEM

 

Specifications:

  • Conductor:?Tinned Copper
  • Insulation: Halogen-Free, Flame-Retardant PVC
  • Certification: UL, RoHS
$999.00

Specifications

Conductors

Material:High-purity annealed copper, compliant with ASTM B-3/B-8 standards, ensuring low resistance and superior conductivity.

Construction:Fine-stranded, multi-conductor design (Class 5 or 6 stranding) for enhanced flexibility and bend resistance.

Coating:Optional tin-plated finish for improved corrosion resistance, ideal for humid or chemically aggressive environments.

Separator

Function:A halogen-free polyester tape or mica barrier layer may be included between the conductor and insulation for mechanical protection and electrical stability.

Material:Halogen-free materials ensure thermal and dielectric reliability under high temperatures.

Voltage Rating

Rated Voltage:300V or 600V, compliant with UL standards for low-voltage power and control systems.

Applications:Suitable for AC/DC circuits in industrial machinery, building wiring, and automation systems.

Insulation & Jacket Materials

Insulation:Cross-linked polyolefin (XLPO) or LSZH (Low Smoke Zero Halogen) thermoplastic for high dielectric strength and heat resistance.

Jacket:Halogen-free thermoplastic elastomer (TPE) or polyolefin, delivering mechanical durability and flame retardancy.

Key Features

Flame Retardant:Passes UL VW-1 vertical flame test.

Eco-Friendly:Free from halogens (Cl, Br), lead, and cadmium; complies with RoHS and REACH regulations.

Resistance Properties

Conductor DC Resistance:Meets UL 1581 standards (e.g., ¡Ü5.21 ¦¸/km for 20 AWG at 20¡ãC).

Insulation Resistance:¡Ý500 M¦¸¡¤km at 20¡ãC (tested at 500V DC).

Temperature Range

Continuous Operation:Rated for 90¡ãC.

Operating Range:-40¡ãC to +105¡ãC, resistant to thermal cycling in harsh environments.

Short-Circuit Tolerance:Withstands +250¡ãC for up to 5 seconds (per UL 1581).

Certification:Passes UL long-term aging tests (e.g., UL 1581 Section 50).

Related Products

UL4348 - THUN-CT

UL4348

Eco-friendly, low-smoke/corrosive gas-free cables for high-safety transport, medical, and building installations.

Custom Wire Harness Solutions - THUN-CT

Custom Wire Harness Solutions

Custom Wire Harness Solutions ¨C Wire Specification Table Conductor Insulation Max Resistance (¦¸/km, 20¡ãC) Dielectric Strength (VAC, 1min) Size (AWG):?Custom (40-4/0) Material:?Silicone, PVC, TPE, XLPE,

Automotive Standard Wire Harness - THUN-CT

Automotive Standard Wire Harness

Automotive Standard Wire Harness Specifications Conductor Insulation Max Resistance (¦¸/km, 20¡ãC) Dielectric Strength (VAC, 1min) Size (AWG):?8-20 Material:?XLPE Construction: Thickness:?0.6-1.0mm 133/0.3mm (8AWG) O.D:?4.5-8.2mm ¡Ü2.1 (8AWG)

REQUEST A QUOTE

Complete the form below and briefly explain your business needs, which will help us route your quote request to the appropriate team member.