Email
Email:thunct1007@gmail.com
WhatsApp

LiHH

Zero Toxicity · Precision Wiring · Industrial Toughness:

  • Self-Extinguishing in 3s:UL VW-1 flame test certified, <15% smoke density (IEC 61034) for control panels & robotics.
  • Halogen-Free & RoHS 3:0ppm chlorine/bromine emissions, compliant with EU Directive 2011/65/EU.
  • 600V Voltage Master:Stable at -40°C to +105°C, ideal for EV charging modules & PLC systems.
  • Abrasion-Proof Jacket:3X longer lifespan than PVC wires (EN 50396 tested), resists oils and solvents.
$999.00

Specifications

Conductors

Ultra-Pure Tinned Copper Core:

Material:99.97% electrolytic copper with 3μm tin coating (IEC 60228 Class 5)

Sizes:AWG 32 (0.03mm²) to AWG 8 (8.37mm²)

Flexibility:65 bends/inch without fracture (ASTM B1/B3 tested)

Separator

Reinforced Interlayer Protection:

Layer 1:Mylar polyester film (0.025mm) for dielectric strength

Layer 2:Aramid fiber braid (200D) for tensile reinforcement

Function:Prevents conductor migration in high-vibration environments

Voltage Rating

600V AC/DC Continuous Operation:

Surge Capacity:Withstands 3kV transient spikes (UL 1581 Section 900)

Key Application:Motor control panels, EV onboard chargers

Insulation & Jacket Materials

Dual-Layer Flame Defense

Layer Material Certification
Insulation Cross-linked polyolefin (XLPO) UL 758 QPLJ8.E12345
Jacket Halogen-free thermoplastic elastomer (TPE) IEC 60754-1 (pH >6.0)
Performance Self-extinguishing in 3s (UL VW-1) Smoke density <15% (IEC 61034-2)

 

Resistance Properties

Engineered to Endure

Challenge Performance Test Standard
Abrasion 30,000+ cycles (1kg load) EN 50396
Chemicals Resists oil/IPA/diesel (72h immersion) ISO 1817
Heat Aging 7-day @ 136°C with <20% conductivity loss UL 1581 Sec. 470
Flame Vertical flame spread ≤50mm IEC 60332-1-2

 

Temperature Range

-40°C to +105°C Operational:

Cold Flexibility:No cracking at -55°C (MIL-W-16878/4)

Heat Resistance:30-minute survival @ 150°C (short-circuit conditions)

Related Products

UL4348 - THUN-CT

UL4348

Eco-friendly, low-smoke/corrosive gas-free cables for high-safety transport, medical, and building installations.

Custom Wire Harness Solutions - THUN-CT

Custom Wire Harness Solutions

Custom Wire Harness Solutions ¨C Wire Specification Table Conductor Insulation Max Resistance (¦¸/km, 20¡ãC) Dielectric Strength (VAC, 1min) Size (AWG):?Custom (40-4/0) Material:?Silicone, PVC, TPE, XLPE,

Automotive Standard Wire Harness - THUN-CT

Automotive Standard Wire Harness

Automotive Standard Wire Harness Specifications Conductor Insulation Max Resistance (¦¸/km, 20¡ãC) Dielectric Strength (VAC, 1min) Size (AWG):?8-20 Material:?XLPE Construction: Thickness:?0.6-1.0mm 133/0.3mm (8AWG) O.D:?4.5-8.2mm ¡Ü2.1 (8AWG)

REQUEST A QUOTE

Complete the form below and briefly explain your business needs, which will help us route your quote request to the appropriate team member.