Email
Email:THUNCT2009@gmail.com
WhatsApp

LiYCY

EMI/RFI Shielding Excellence:

  • Triple-layer copper braid + aluminum foil shielding.
  • 90% interference suppression for signal integrity.

Industrial Toughness:

  • Oil-resistant PVC outer jacket (IP67 rated).
  • Withstands -40°C to 105°C (-40°F to 221°F).
  • 20M+ bend cycles tested.

Flexible & Easy Installation:

  • Ultra-fine stranded conductors.
  • 180° torsion capability for tight spaces.

Global Compliance Ready:

  • CE, RoHS, REACH certified.
  • UL-recognized materials (optional).

Trusted in Critical Applications:

  • Factory Automation Systems.
  • CNC Machinery & Robotics.
  • Renewable Energy Installations.
  • Process Control Panels.

 

Tailored to Your Needs:

  • Custom lengths (1m to 1000m).
  • Color-coding & printing options.
  • Drum/Coil packaging + RFID tagging.

Supply Chain You Can Rely On:

  • ISO 9001-certified production.
  • 48-hour express quoting.
  • DDP shipping worldwide.

Specifiche tecniche

Conduttori

High-Flexibility Tinned Copper:

Materiale:99.97% electrolytic copper with Sn coating

Stranding:0.10mm ultra-fine strands (32/0.10)

Gauge Range:24 AWG to 12 AWG (0.25mm² – 4.0mm²)

Key Advantage:12% lower DC resistance vs. bare copper (≤0.017 Ω/m @20°C)
Anti-corrosion for humid/chemical environments

Separatore

Dual-Layer EMI Shielding:

Inner Layer:Aluminum-polyester foil (100% coverage)

Outer Layer:Tinned copper braid (85% coverage)

Key Advantage:98% EMI/RFI suppression (tested per EN 50289-1-6)
Integrated drain wire for grounding reliability

Tensione nominale

Dual-Layer EMI Shielding:

Inner Layer:Aluminum-polyester foil (100% coverage)

Outer Layer:Tinned copper braid (85% coverage)

Key Advantage:98% EMI/RFI suppression (tested per EN 50289-1-6)
Integrated drain wire for grounding reliability

Isolamento e rivestimento Materiali

Triple-Protected Design:

Conductor Insulation:PVC, color-coded per DIN 47100

Inner Sheath:PVC with oil resistance (ISO 1817 tested)

Outer Jacket:Heavy-duty PVC (IP67 rating when glanded)

Key Advantage:10X abrasion resistance vs. standard PVC (ISO 6722)

Proprietà di resistenza

Engineered for Signal Integrity

Parameter Value Test Standard
Insulation Resistance ≥20 MΩ·km (500V DC) IEC 60811-1
Capacitance Unbalance ≤100 pF/100m EN 50288-7
Transfer Impedance ≤50 mΩ/m @100MHz IEC 62153-4-3

Intervallo di temperatura

Engineered for Signal Integrity

Parameter Value Test Standard
Insulation Resistance ≥20 MΩ·km (500V DC) IEC 60811-1
Capacitance Unbalance ≤100 pF/100m EN 50288-7
Transfer Impedance ≤50 mΩ/m @100MHz IEC 62153-4-3

Prodotti correlati

UL3173 - THUN-CT

UL3173

UL3173 Specifiche Foglio Conduttore Isolamento Resistenza massima del conduttore (Ω/Km, 20℃) Rigidità dielettrica (Vac, 1min) Dimensioni (AWG) Costruzione (No/mm) Dia (mm) Spessore (mm) O.D (mm) 26 7/0,160 0,48 0,76 2,10

UL3265 - THUN-CT

UL3265

Specifiche UL3265 Isolamento del conduttore Resistenza massima del conduttore (Ω/Km,20℃) Rigidità dielettrica (Vac,1min) Dimensioni (AWG) Costruzione (No/mm) Diametro (mm) Spessore (mm) O.D (mm) 32 7/0,080 0,24 0,26 0,80 596 1500 30

UL3266 - THUN-CT

UL3266

UL3266 Specifiche Foglio Conduttore Isolamento Resistenza massima del conduttore (Ω/Km, 20℃) Rigidità dielettrica (Vac, 1min) Dimensioni (AWG) Costruzione (No/mm) Dia (mm) Spessore (mm) O.D (mm) 30 7/0,100 0,30 0,38 1,10 381 2000

UL3302 - THUN-CT

UL3302

Isolamento del conduttore Resistenza massima del conduttore (Ω/Km,20℃) Rigidità dielettrica (Vac,1min) Dimensione (AWG) Costruzione (No/mm) Dia (mm) Spessore (mm) O.D (mm) 32 7/0,080 0,24 0,20 0,65 596 500 30 7/0,100

RICHIEDERE UN PREVENTIVO