LiYCY PVC Shielded Control Cable

  1. Casa
  2. /
  3. Prodotti
  4. /
  5. LiYCY PVC Shielded Control...

LiYCY PVC Shielded Control Cable

EMI/RFI Shielding Excellence

  • Triple-layer copper braid + aluminum foil shielding
  • 90% interference suppression for signal integrity

 

Industrial Toughness

  • Oil-resistant PVC outer jacket (IP67 rated)
  • Withstands -40°C to 105°C (-40°F to 221°F)
  • 20M+ bend cycles tested

 

Flexible & Easy Installation

  • Ultra-fine stranded conductors
  • 180° torsion capability for tight spaces

 

Global Compliance Ready

  • CE, RoHS, REACH certified
  • UL-recognized materials (optional)

 

Trusted in Critical Applications

  • Factory Automation Systems
  • CNC Machinery & Robotics
  • Renewable Energy Installations
  • Process Control Panels

 

Tailored to Your Needs

  • Custom lengths (1m to 1000m)
  • Color-coding & printing options
  • Drum/Coil packaging + RFID tagging

 

Supply Chain You Can Rely On

  • ISO 9001-certified production
  • 48-hour express quoting
  • DDP shipping worldwide

Specifiche tecniche

Conductors

High-Flexibility Tinned Copper

Material: 99.97% electrolytic copper with Sn coating

Stranding: 0.10mm ultra-fine strands (32/0.10)

Gauge Range: 24 AWG to 12 AWG (0.25mm² – 4.0mm²)

Key Advantage:

12% lower DC resistance vs. bare copper (≤0.017 Ω/m @20°C)
Anti-corrosion for humid/chemical environments

Separator

Dual-Layer EMI Shielding

Inner Layer: Aluminum-polyester foil (100% coverage)

Outer Layer: Tinned copper braid (85% coverage)

Key Advantage:

98% EMI/RFI suppression (tested per EN 50289-1-6)
Integrated drain wire for grounding reliability

Voltage Rating

Dual-Layer EMI Shielding

Inner Layer: Aluminum-polyester foil (100% coverage)

Outer Layer: Tinned copper braid (85% coverage)

Key Advantage:

98% EMI/RFI suppression (tested per EN 50289-1-6)
Integrated drain wire for grounding reliability

Insulation & Jacket Materials

Triple-Protected Design

Conductor Insulation: PVC, color-coded per DIN 47100

Inner Sheath: PVC with oil resistance (ISO 1817 tested)

Outer Jacket: Heavy-duty PVC (IP67 rating when glanded)

Key Advantage:

10X abrasion resistance vs. standard PVC (ISO 6722)

Resistance Properties

Engineered for Signal Integrity

Parameter Value Test Standard
Insulation Resistance ≥20 MΩ·km (500V DC) IEC 60811-1
Capacitance Unbalance ≤100 pF/100m EN 50288-7
Transfer Impedance ≤50 mΩ/m @100MHz IEC 62153-4-3

Temperature Range

Engineered for Signal Integrity

Parameter Value Test Standard
Insulation Resistance ≥20 MΩ·km (500V DC) IEC 60811-1
Capacitance Unbalance ≤100 pF/100m EN 50288-7
Transfer Impedance ≤50 mΩ/m @100MHz IEC 62153-4-3

Prodotti correlati

UL4348 Halogen-Free Wires

UL4348 Specifications Sheet   Pitch (mm) Conductor Insulation Resistance  At 20C Ω/km   Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia. (mm) (No.) Thickness (mm) O.D (mm)        

Soluzioni di cablaggio personalizzate

Soluzioni per cablaggi personalizzati - Tabella delle specifiche dei fili Conduttore Isolamento Resistenza massima (Ω/km, 20°C) Rigidità dielettrica (VAC, 1min) Dimensioni (AWG): Personalizzato (40-4/0) Materiale: Silicone, PVC, TPE, XLPE,

Cablaggio standard per autoveicoli

Specifiche del cablaggio standard per autoveicoli Isolamento del conduttore Resistenza massima (Ω/km, 20°C) Rigidità dielettrica (VAC, 1min) Dimensioni (AWG): 8-20 Materiale: XLPE Costruzione: Spessore: 0,6-1,0 mm 133/0,3 mm (8AWG) O.D: 4,5-8,2 mm ≤2,1 (8AWG)

RICHIEDERE UN PREVENTIVO

Compilate il modulo sottostante e spiegate brevemente le vostre esigenze aziendali; in questo modo potremo inoltrare la vostra richiesta di preventivo al membro del team più adatto.