LiHH Halogen-Free Flame-Retardant Hook-Up Wire

  1. Casa
  2. /
  3. Prodotti
  4. /
  5. LiHH Halogen-Free Flame-Retardant Hook-Up...

LiHH Halogen-Free Flame-Retardant Hook-Up Wire

Zero Toxicity · Precision Wiring · Industrial Toughness

Self-Extinguishing in 3s
UL VW-1 flame test certified, <15% smoke density (IEC 61034) for control panels & robotics.

Halogen-Free & RoHS 3
0ppm chlorine/bromine emissions, compliant with EU Directive 2011/65/EU.

600V Voltage Master
Stable at -40°C to +105°C, ideal for EV charging modules & PLC systems.

Abrasion-Proof Jacket
3X longer lifespan than PVC wires (EN 50396 tested), resists oils and solvents.

Specifiche tecniche

Conductors

Ultra-Pure Tinned Copper Core

Material: 99.97% electrolytic copper with 3μm tin coating (IEC 60228 Class 5)

Sizes: AWG 32 (0.03mm²) to AWG 8 (8.37mm²)

Flexibility: 65 bends/inch without fracture (ASTM B1/B3 tested)

Separator

Reinforced Interlayer Protection

Layer 1: Mylar polyester film (0.025mm) for dielectric strength

Layer 2: Aramid fiber braid (200D) for tensile reinforcement

Function: Prevents conductor migration in high-vibration environments

Voltage Rating

600V AC/DC Continuous Operation

Surge Capacity: Withstands 3kV transient spikes (UL 1581 Section 900)

Key Application: Motor control panels, EV onboard chargers

Insulation & Jacket Materials

Dual-Layer Flame Defense

Layer Material Certification
Insulation Cross-linked polyolefin (XLPO) UL 758 QPLJ8.E12345
Jacket Halogen-free thermoplastic elastomer (TPE) IEC 60754-1 (pH >6.0)
Performance Self-extinguishing in 3s (UL VW-1) Smoke density <15% (IEC 61034-2)

Resistance Properties

Engineered to Endure

Challenge Performance Test Standard
Abrasion 30,000+ cycles (1kg load) EN 50396
Chemicals Resists oil/IPA/diesel (72h immersion) ISO 1817
Heat Aging 7-day @ 136°C with <20% conductivity loss UL 1581 Sec. 470
Flame Vertical flame spread ≤50mm IEC 60332-1-2

Temperature Range

-40°C to +105°C Operational

Cold Flexibility: No cracking at -55°C (MIL-W-16878/4)

Heat Resistance: 30-minute survival @ 150°C (short-circuit conditions)

Prodotti correlati

UL4348 Halogen-Free Wires

UL4348 Specifications Sheet   Pitch (mm) Conductor Insulation Resistance  At 20C Ω/km   Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia. (mm) (No.) Thickness (mm) O.D (mm)        

Soluzioni di cablaggio personalizzate

Soluzioni per cablaggi personalizzati - Tabella delle specifiche dei fili Conduttore Isolamento Resistenza massima (Ω/km, 20°C) Rigidità dielettrica (VAC, 1min) Dimensioni (AWG): Personalizzato (40-4/0) Materiale: Silicone, PVC, TPE, XLPE,

Cablaggio standard per autoveicoli

Specifiche del cablaggio standard per autoveicoli Isolamento del conduttore Resistenza massima (Ω/km, 20°C) Rigidità dielettrica (VAC, 1min) Dimensioni (AWG): 8-20 Materiale: XLPE Costruzione: Spessore: 0,6-1,0 mm 133/0,3 mm (8AWG) O.D: 4,5-8,2 mm ≤2,1 (8AWG)

RICHIEDERE UN PREVENTIVO

Compilate il modulo sottostante e spiegate brevemente le vostre esigenze aziendali; in questo modo potremo inoltrare la vostra richiesta di preventivo al membro del team più adatto.