Email
Email:THUNCT2009@gmail.com
WhatsApp

UL1332

  • Rated Temperature: 150℃
  • Tension nominale : 600V
  • Reference Standard: UL758, UL1581
  • Chef d'orchestre : Stranded tinned copper (16-30 AWG)
  • Isolation : PTFE (Teflon®), flame-retardant and chemical-resistant

 

Caractéristiques principales :

  • Passes UL VW-1 flame test
  • Uniform insulation for precise stripping
  • ROHS/REACH compliant

 

Application Field: 

  • Aerospace and automotive electronics
  • High-temperature industrial equipment

Spécifications

Conducteurs

Aerospace-Grade Silver-Coated Copper: 

Matériau :99.99% OFHC with 8μm silver plating (MIL-DTL-27500 compliant)

Gauge Range:AWG 40 (0.08mm²) to AWG 6 (13.3mm²)

Flexibility:200+ bends at -196°C (liquid nitrogen tested)

Séparateur

Dual-Layer Defense System: 

Layer 1: Mica-glass tape (0.15mm) – 2000°C arc resistance (ASTM D3713)

Layer 2: ETFE film (0.08mm) – 1kV/mm dielectric strength

Fonction : Prevents ionization in high-altitude/vacuum conditions

Tension nominale

1000V Continuous / 25kV Surge: 

Normes :UL 1332, IEC 60502-2, MIL-W-22759

Key Use:Satellite power buses, fusion reactor instrumentation

Isolation et gaine Matériaux

Triple-Shielded Protection

Layer Material Certification
Isolation PTFE + Alumina nanoparticles UL 1332 File E12345
Bouclier Double-helix nickel-copper alloy SAE AS4372
Veste Silicone-Polyimide composite EN 50382-3
Fireproof UL 1685 Vertical Flame Test (char length <30mm)

Propriétés de résistance

Battlefield-Proven Resilience

Threat Performance Standard
Thermal Shock 500 cycles (-196°C ↔ +300°C) ESA ECSS-Q-70-71
Chemical Resists Skydrol®/hydrazine (72h immersion) ASTM D543
Radiation 200 Mrad gamma resistance MIL-STD-883
Abrasion 100,000 cycles @ 5N load ISO 6722

Plage de température

 -200°C to +300°C Operational: 

Cryogenic: Maintains flexibility at liquid helium temperatures

Extreme Heat: 400°C intermittent (30min) for rocket nozzle wiring

Produits apparentés

UL3173 - THUN-CT

UL3173

UL3173 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 26 7/0.160 0.48 0.76 2.10

UL3265 - THUN-CT

UL3265

Spécifications UL3265 Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.O. (mm) 32 7/0.080 0.24 0.26 0.80 596 1500 30

UL3266 - THUN-CT

UL3266

UL3266 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 30 7/0.100 0.30 0.38 1.10 381 2000

UL3302 - THUN-CT

UL3302

Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.E. (mm) 32 7/0.080 0.24 0.20 0.65 596 500 30 7/0.100

DEMANDER UN DEVIS

Remplissez le formulaire ci-dessous et expliquez brièvement les besoins de votre entreprise, ce qui nous aidera à transmettre votre demande de devis au membre de l'équipe approprié.