Email
Email:THUNCT2009@gmail.com
WhatsApp

UL1185

Engineered for Industrial Precision. Built for Reliability

Superior EMI/RFI Shielding:

  • Precision signal transmission in high-interference environments.

Certifié UL Sécurité :

  • Complies with UL 1185 standards for industrial-grade fire resistance and durability.

Heavy-Duty Protection:

  • Double-layer shielding + abrasion-resistant jacket withstands extreme temperatures (-40°C to 105°C).

Zero Downtime Guarantee:

  • Shielded twisted pair design minimizes crosstalk – critical for automation & control systems.

Global Compliance Ready:

  • Conforme aux normes CE, RoHS et REACH pour un déploiement international sans faille.

Applications :

  •  Factory Automation ◼️ Motor Controls ◼️ PLC Systems ◼️ Robotics

Spécifications

Conducteurs

Cuivre étamé de haute pureté :

Low-resistance conductors ensure stable signal integrity even over long distances.

Tin-plated design prevents oxidation, extending lifespan in humid or corrosive conditions.

Séparateur

Advanced Dielectric Core Separation:

Precision-wrapped foil separator eliminates internal interference between pairs.

Maintains consistent impedance for PLCs, servo motors, and high-frequency systems.

Tension nominale

300V Rated for Industrial Safety:

Withstands voltage surges common in motor control and automation cabinets.

UL-tested insulation ensures compliance with OSHA and NFPA 70E standards.

Isolation et gaine Matériaux

Dual-Layer Defense:

Isolation intérieure :Cross-linked PVC (XL-PVC) resists oils, chemicals, and abrasion.

Veste extérieure :Heavy-duty PUR (Polyurethane) with UV resistance for indoor/outdoor flexibility (-40°C to 105°C).

Propriétés de résistance

Engineered for Signal Integrity:

≤20Ω/km conductor resistance | ≥90% shielding coverage

Twisted pair + braided shield reduces EMI by 95% vs. unshielded cables.

Plage de température

Prêt pour les environnements extrêmes :

Plage de fonctionnement :De -40°C à +105°C

Flame-retardant materials (UL VW-1 rated) prevent melting in high-heat industrial panels.

Produits apparentés

UL3173 - THUN-CT

UL3173

UL3173 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 26 7/0.160 0.48 0.76 2.10

UL3265 - THUN-CT

UL3265

Spécifications UL3265 Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.O. (mm) 32 7/0.080 0.24 0.26 0.80 596 1500 30

UL3266 - THUN-CT

UL3266

UL3266 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 30 7/0.100 0.30 0.38 1.10 381 2000

UL3302 - THUN-CT

UL3302

Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.E. (mm) 32 7/0.080 0.24 0.20 0.65 596 500 30 7/0.100

DEMANDER UN DEVIS

Remplissez le formulaire ci-dessous et expliquez brièvement les besoins de votre entreprise, ce qui nous aidera à transmettre votre demande de devis au membre de l'équipe approprié.