Engineered for Harsh Environments, Built for Industrial Reliability

Ultra-Durable PVC Armor:

  • UV-resistant & waterproof jacket withstands -40°C to +70°C extremes

Global Compliance Guaranteed:

  • Certified to IEC 60502-1 | CE & RoHS compliant

Flame-Retardant Safety:

  • Low-smoke, halogen-free design (IEC 60332-1)

High-Capacity Wiring:

  • 3-core + ground | 1.5-10mm² options for heavy-duty systems

Rapid Deployment Ready:

  • Pre-lubricated sheath for 30% faster installation

Spécifications

Conducteurs

Noyau en cuivre de haute pureté :Multi-stranded design (Class 5 per IEC 60228) ensures flexibility + 99.9% conductivity efficiency

3-Core + Ground Configuration:Available in 1.5mm² to 10mm² for heavy-load applications (motors, solar inverters, etc.)

Séparateur

Noyau en cuivre de haute pureté :Multi-stranded design (Class 5 per IEC 60228) ensures flexibility + 99.9% conductivity efficiency

3-Core + Ground Configuration:Available in 1.5mm² to 10mm² for heavy-load applications (motors, solar inverters, etc.)

Tension nominale

0.6/1kV Robust Performance:Stable power transmission for industrial machinery & renewable energy systems

Protection contre les surtensions :Withstands 4kV lightning impulse (IEC 60502-1 tested)

Isolation et gaine Matériaux

Double-Layer Armor:Inner PVC insulation + Outer UV-resistant PVC jacket (IP67 waterproof rating)

Abrasion-Proof Design:20% thicker than standard cables for trench/underground deployment

Propriétés de résistance

Threat Performance Data Certifications
Chemicals Resists oils, acids, alkalis IEC 60811-3-1
Temperature -40°C to +70°C operation EN 50618:2014
Flame Spread Self-extinguishing in 30s IEC 60332-1-2

Plage de température

Year-Round Reliability:From Arctic cold (-40°C) to desert heat (+70°C) without brittleness or melting

Pic à court terme :Survives +105°C overloads (emergency scenarios)

Produits apparentés

UL3173 - THUN-CT

UL3173

UL3173 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 26 7/0.160 0.48 0.76 2.10

UL3265 - THUN-CT

UL3265

Spécifications UL3265 Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.O. (mm) 32 7/0.080 0.24 0.26 0.80 596 1500 30

UL3266 - THUN-CT

UL3266

UL3266 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 30 7/0.100 0.30 0.38 1.10 381 2000

UL3302 - THUN-CT

UL3302

Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.E. (mm) 32 7/0.080 0.24 0.20 0.65 596 500 30 7/0.100

DEMANDER UN DEVIS

Remplissez le formulaire ci-dessous et expliquez brièvement les besoins de votre entreprise, ce qui nous aidera à transmettre votre demande de devis au membre de l'équipe approprié.