Email
Email:THUNCT2009@gmail.com
WhatsApp

NYM-J

Engineered for Industrial Excellence

Certified Safety:

  • CE & IEC 60227 Compliant | Flame Retardant & 70°C Heat Resistance.

Ultra-Durable Design:

  • Reinforced PVC Insulation | Anti-Corrosion & Abrasion-Resistant.

Applications polyvalentes :

  • Ideal for Machinery, Construction & Infrastructure Wiring.

Tailored Solutions:

  • Custom Sizes (2.5-120mm²) | Lengths & Color Coding Options.

Spécifications

Conducteurs

Noyau en cuivre de haute pureté :

Matériau :99.9% annealed copper conductors

Benefits:Superior conductivity, low energy loss, and long-term durability

Flexibility:Optimized strand design for easy installation in tight spaces

Séparateur

Integrated Protective Layer:

Matériau :PVC separator between conductors

Fonction :Prevents electrical interference, enhances insulation integrity

Safety:Reduces short-circuit risks in multi-core configurations

Tension nominale

Robust Performance Under Load:

Tension nominale :300/500V

Conformité :IEC 60227 & VDE standards

Applications :Suitable for fixed installations in dry/humid conditions

Isolation et gaine Matériaux

Double-Layer Defense:

Isolation :Flame-retardant PVC (FR-LSZH option available)

Veste :Reinforced PVC with anti-UV additives

Protection:IP54 rated against dust/moisture, abrasion-resistant

Propriétés de résistance

Engineered for Reliability:

Fire Safety:IEC 60332-1 flame propagation tested

Résistance chimique :Oil, acid, and alkali protection (IEC 60811 compliant)

Aging Resistance:20+ years lifespan under standard conditions

Plage de température

Adaptation aux conditions extrêmes :

Plage de fonctionnement :-20°C to +70°C

Peak Tolerance:Short-term resistance up to +90°C

Certification :70°C continuous rating (IEC 60227)

Produits apparentés

UL3173 - THUN-CT

UL3173

UL3173 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 26 7/0.160 0.48 0.76 2.10

UL3265 - THUN-CT

UL3265

Spécifications UL3265 Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.O. (mm) 32 7/0.080 0.24 0.26 0.80 596 1500 30

UL3266 - THUN-CT

UL3266

UL3266 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 30 7/0.100 0.30 0.38 1.10 381 2000

UL3302 - THUN-CT

UL3302

Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.E. (mm) 32 7/0.080 0.24 0.20 0.65 596 500 30 7/0.100

DEMANDER UN DEVIS

Remplissez le formulaire ci-dessous et expliquez brièvement les besoins de votre entreprise, ce qui nous aidera à transmettre votre demande de devis au membre de l'équipe approprié.