Email
Email:THUNCT2009@gmail.com
WhatsApp

LiHH

Zero Toxicity · Precision Wiring · Industrial Toughness:

  • Self-Extinguishing in 3s:UL VW-1 flame test certified, <15% smoke density (IEC 61034) for control panels & robotics.
  • Halogen-Free & RoHS 3:0ppm chlorine/bromine emissions, compliant with EU Directive 2011/65/EU.
  • 600V Voltage Master:Stable at -40°C to +105°C, ideal for EV charging modules & PLC systems.
  • Abrasion-Proof Jacket:3X longer lifespan than PVC wires (EN 50396 tested), resists oils and solvents.

Spécifications

Conducteurs

Ultra-Pure Tinned Copper Core:

Matériau :99.97% electrolytic copper with 3μm tin coating (IEC 60228 Class 5)

Tailles :AWG 32 (0.03mm²) to AWG 8 (8.37mm²)

Flexibility:65 bends/inch without fracture (ASTM B1/B3 tested)

Séparateur

Reinforced Interlayer Protection:

Layer 1:Mylar polyester film (0.025mm) for dielectric strength

Layer 2:Aramid fiber braid (200D) for tensile reinforcement

Fonction :Prevents conductor migration in high-vibration environments

Tension nominale

600V AC/DC Continuous Operation:

Surge Capacity:Withstands 3kV transient spikes (UL 1581 Section 900)

Key Application:Motor control panels, EV onboard chargers

Isolation et gaine Matériaux

Dual-Layer Flame Defense

Layer Material Certification
Isolation Cross-linked polyolefin (XLPO) UL 758 QPLJ8.E12345
Veste Halogen-free thermoplastic elastomer (TPE) IEC 60754-1 (pH >6.0)
Performance Self-extinguishing in 3s (UL VW-1) Smoke density <15% (IEC 61034-2)

Propriétés de résistance

Engineered to Endure

Challenge Performance Test Standard
Abrasion 30,000+ cycles (1kg load) EN 50396
Chemicals Resists oil/IPA/diesel (72h immersion) ISO 1817
Heat Aging 7-day @ 136°C with <20% conductivity loss UL 1581 Sec. 470
Flame Vertical flame spread ≤50mm IEC 60332-1-2

Plage de température

-40°C to +105°C Operational:

Cold Flexibility:No cracking at -55°C (MIL-W-16878/4)

Résistance à la chaleur :30-minute survival @ 150°C (short-circuit conditions)

Produits apparentés

UL3173 - THUN-CT

UL3173

UL3173 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 26 7/0.160 0.48 0.76 2.10

UL3265 - THUN-CT

UL3265

Spécifications UL3265 Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.O. (mm) 32 7/0.080 0.24 0.26 0.80 596 1500 30

UL3266 - THUN-CT

UL3266

UL3266 Specifications Sheet Conductor Insulation Maximum Conductor Resistance (Ω/Km,20℃) Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia (mm) Thickness (mm) O.D (mm) 30 7/0.100 0.30 0.38 1.10 381 2000

UL3302 - THUN-CT

UL3302

Isolation du conducteur Résistance maximale du conducteur (Ω/Km,20℃) Rigidité diélectrique (Vac,1min) Taille (AWG) Construction (No/mm) Dia (mm) Épaisseur (mm) D.E. (mm) 32 7/0.080 0.24 0.20 0.65 596 500 30 7/0.100

DEMANDER UN DEVIS

Remplissez le formulaire ci-dessous et expliquez brièvement les besoins de votre entreprise, ce qui nous aidera à transmettre votre demande de devis au membre de l'équipe approprié.