Email
Email:THUNCT2009@gmail.com
WhatsApp

LiYCY-TP

Superior Signal Integrity:

  • Dual shielding: Aluminum foil + tinned copper braid.
  • <0.5% crosstalk | 100MHz+ bandwidth for precision data.

Industrial Noise Immunity:

  • 360° EMI/RFI shielding (98% efficiency).
  • Twisted pair design cancels electromagnetic interference.
  • UV-resistant PVC jacket (IP68 when glanded).

Extreme Environment Ready:

  • -40°C to +80°C (-40°F to +176°F) operation.
  • Resists oils, acids, and abrasion (EN 50382-3 compliant).

Plug-and-Play Flexibility:

  • 0.75mm² to 2.5mm² conductor options.
  • 600V rated | 5000+ bend cycles tested.

Global Compliance:

  • CE, RoHS, REACH, UL/CSA (on request).
  • Meets EN 50288 & IEC 61158-2 standards.

Mission-Critical Applications:

  • Industrial Ethernet (PROFINET/EtherCAT).
  • Building Automation Networks.
  • Railway Signaling Systems.
  • Robotic Sensor Arrays.

Custom-Built for Your Project:

  • Cut-to-length (1m–500m).
  • Color-coded pairs + laser printing.
  • Armored version available.

 

Reliable Supply Chain:

  • ISO 9001 & IRIS certified factories.
  • 48h rapid prototyping.
  • FCA/EXW/DDP terms.

Especificaciones

Conductores

Oxygen-Free Twisted Copper Pair:

Material:99.95% electrolytic copper with Sn/Cu coating

Stranding:0.12mm precision strands (2×24 AWG)

Twist Rate:4 twists/cm (EN 50288-7 compliant)

Key Advantage:18% lower signal attenuation vs. standard UTP
50μΩ/cm max. loop resistance (IEC 61156-1 tested)

Separador

Oxygen-Free Twisted Copper Pair:

Material:99.95% electrolytic copper with Sn/Cu coating

Stranding:0.12mm precision strands (2×24 AWG)

Twist Rate:4 twists/cm (EN 50288-7 compliant)

Key Advantage:18% lower signal attenuation vs. standard UTP
50μΩ/cm max. loop resistance (IEC 61156-1 tested)

Tensión nominal

Oxygen-Free Twisted Copper Pair:

Material:99.95% electrolytic copper with Sn/Cu coating

Stranding:0.12mm precision strands (2×24 AWG)

Twist Rate:4 twists/cm (EN 50288-7 compliant)

Key Advantage:18% lower signal attenuation vs. standard UTP
50μΩ/cm max. loop resistance (IEC 61156-1 tested)

Aislamiento y cubierta Materiales

Armored for Industrial Abuse:

Conductor Insulation:Foam-skin PE (0.8mm thickness)

Inner Sheath:FRPVC with UV stabilizers

Outer Jacket:Heavy-duty PVC (IP69K when sealed)

Key Advantage:200kg tensile strength (ISO 6722 Class 5)
Chemical resistance to oils/alkalis (ISO 1817)

Propiedades de resistencia

Precision Signal Transmission

Parameter Value Test Standard
Characteristic Impedance 120Ω ±10% @100MHz IEC 61156-1
DC Loop Resistance ≤57Ω/km EN 50288-7
Insulation Resistance ≥5000MΩ·km (500V DC) IEC 60811-1

Temperatura

Precision Signal Transmission

Parameter Value Test Standard
Characteristic Impedance 120Ω ±10% @100MHz IEC 61156-1
DC Loop Resistance ≤57Ω/km EN 50288-7
Insulation Resistance ≥5000MΩ·km (500V DC) IEC 60811-1

Productos relacionados

UL3173 - THUN-CT

UL3173

Especificaciones UL3173 Hoja Conductor Aislamiento Resistencia máxima del conductor (Ω/Km,20℃) Rigidez dieléctrica (Vac,1min) Tamaño (AWG) Construcción (No/mm) Diámetro (mm) Espesor (mm) D.E. (mm) 26 7/0.160 0.48 0.76 2.10

UL3265 - THUN-CT

UL3265

Especificaciones UL3265 Aislamiento del conductor Resistencia máxima del conductor (Ω/Km,20℃) Rigidez dieléctrica (Vac,1min) Tamaño (AWG) Construcción (No/mm) Diámetro (mm) Espesor (mm) Diámetro exterior (mm) 32 7/0,080 0,24 0,26 0,80 596 1500 30

UL3266 - THUN-CT

UL3266

Especificaciones UL3266 Hoja Conductor Aislamiento Resistencia máxima del conductor (Ω/Km,20℃) Rigidez dieléctrica (Vac,1min) Tamaño (AWG) Construcción (No/mm) Diámetro (mm) Espesor (mm) D.E. (mm) 30 7/0.100 0.30 0.38 1.10 381 2000

UL3302 - THUN-CT

UL3302

Aislamiento del conductor Resistencia máxima del conductor (Ω/Km,20℃) Rigidez dieléctrica (Vac,1min) Tamaño (AWG) Construcción (No/mm) Diámetro (mm) Espesor (mm) D.E. (mm) 32 7/0.080 0,24 0,20 0,65 596 500 30 7/0.100

SOLICITAR PRESUPUESTO

Rellene el siguiente formulario y explique brevemente las necesidades de su empresa, lo que nos ayudará a dirigir su solicitud de presupuesto al miembro del equipo adecuado.