SiHF Silicone High-Temperature Wire (300V-600V)
Conductor (Size, AWG) |
Bauwesen (No/mm) |
Dia (mm) |
Insulation Thickness (mm) |
O.D (mm) |
Max Conductor Resistance (Ω/km, 20°C) |
Dielectric Strength (Vac, 1min) |
24 | 7/0.10 | 0.3 | 0.4 | 1.6 | ≤ 239 | 3000 |
22 | 10/0.10 | 0.4 | 0.5 | 2.0 | ≤ 138 | 3000 |
20 | 16/0.10 | 0.5 | 0.6 | 2.5 | ≤ 86.3 | 3000 |
18 | 26/0.10 | 0.6 | 0.7 | 3.0 | ≤ 54.4 | 3000 |
16 | 41/0.10 | 0.8 | 0.8 | 3.6 | ≤ 34.6 | 3000 |
14 | 65/0.10 | 1.0 | 1.0 | 4.5 | ≤ 21.8 | 3000 |
12 | 105/0.10 | 1.2 | 1.2 | 5.5 | ≤ 13.7 | 3000 |
10 | 168/0.10 | 1.5 | 1.5 | 6.8 | ≤ 8.45 | 3000 |
Notes:
Conductor: Bare copper or optional silver-plated copper for enhanced conductivity.
Insulation: High-temperature silicone rubber (UL 3239 compliant).
Optional Braid: Fiberglass or nylon overjacket for mechanical protection (adds 0.2–0.5mm to O.D).
Standards: UL 3239, VDE 0250, MIL-W-16878/5.