CCCRVVP Shielded Control Cable

  1. Startseite
  2. /
  3. Produkte
  4. /
  5. CCCRVVP Shielded Control Cable

CCCRVVP Shielded Control Cable

Premium Signal Integrity for Sensitive Equipment

  • Dual-Shielded Design – Foil + braid for 95% EMI protection
  • Global Certifications – CCC, CE, RoHS, IEC 60227
  • Flexible & Durable – 50,000+ bend cycles

 

Key Features:

  • Conductor: Oxygen-free copper (0.5-6.0mm²)
  • Voltage: 300/500V
  • Temperature: -40°C to +90°C
  • Colors: 10+ options + custom printing

 

Ideal For:

  • CNC machine controls
  • Servo motor systems
  • Industrial automation
  • Medical imaging equipment

Spezifikationen

Dirigenten

99.97% oxygen-free copper (IEC 60228 Class 5)

Ultra-fine stranding (42-0.15mm for 1.0mm²)

Range: 0.5-6.0mm² (AWG 20-10)

Superior flexibility with 50,000+ bend cycles

Abscheider

Dual shielding:

– Aluminum-polyester foil (100% coverage)

– Tinned copper braid (85% coverage)

Drain wire for grounding

95% EMI/RFI interference rejection

Nennspannung

300/500V AC

4000V dielectric strength tested

100% hipot tested at 2000V

Safe for variable frequency drive environments

Isolierung & Mantel Werkstoffe

Inner insulation: XLPE (0.5-0.8mm)

Outer jacket: Oil-resistant PVC (0.8-1.2mm)

Optional PUR jacket (+300% abrasion resistance)

O.D: 3.8-8.2mm

Withstands industrial chemical exposure

Widerstandseigenschaften

≤39Ω/km (0.5mm²)

>500MΩ insulation resistance (500VDC)

Capacitance balance: <120pF/m

Stable signal transmission in noisy environments

Temperaturbereich

-40°C to +90°C (standard)

-60°C to +105°C (high-temp version)

Performs in foundries/freezer plants

Verwandte Produkte

UL4348 Halogen-Free Wires

UL4348 Specifications Sheet   Pitch (mm) Conductor Insulation Resistance  At 20C Ω/km   Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia. (mm) (No.) Thickness (mm) O.D (mm)        

Kundenspezifische Kabelbaumlösungen

Kundenspezifische Lösungen für Kabelbäume - Tabelle der Kabelspezifikationen Leiter Isolierung Maximaler Widerstand (Ω/km, 20°C) Durchschlagfestigkeit (VAC, 1min) Größe (AWG): Kundenspezifisch (40-4/0) Material: Silikon, PVC, TPE, XLPE,

Kfz-Standard-Kabelbaum

Automobil-Standard-Kabelbaum Spezifikationen Leiter Isolierung Maximaler Widerstand (Ω/km, 20°C) Durchschlagsfestigkeit (VAC, 1min) Größe (AWG): 8-20 Material: XLPE Konstruktion: Dicke: 0,6-1,0mm 133/0,3mm (8AWG) Außendurchmesser: 4,5-8,2mm ≤2,1 (8AWG)

EIN ANGEBOT ANFORDERN

Füllen Sie das nachstehende Formular aus und erläutern Sie kurz Ihre geschäftlichen Anforderungen. So können wir Ihre Angebotsanfrage an das zuständige Teammitglied weiterleiten.