LiHH Halogen-Free Flame-Retardant Hook-Up Wire

  1. Startseite
  2. /
  3. Produkte
  4. /
  5. LiHH Halogen-Free Flame-Retardant Hook-Up...

LiHH Halogen-Free Flame-Retardant Hook-Up Wire

Zero Toxicity · Precision Wiring · Industrial Toughness

Self-Extinguishing in 3s
UL VW-1 flame test certified, <15% smoke density (IEC 61034) for control panels & robotics.

Halogen-Free & RoHS 3
0ppm chlorine/bromine emissions, compliant with EU Directive 2011/65/EU.

600V Voltage Master
Stable at -40°C to +105°C, ideal for EV charging modules & PLC systems.

Abrasion-Proof Jacket
3X longer lifespan than PVC wires (EN 50396 tested), resists oils and solvents.

Spezifikationen

Dirigenten

Ultra-Pure Tinned Copper Core

Material: 99.97% electrolytic copper with 3μm tin coating (IEC 60228 Class 5)

Sizes: AWG 32 (0.03mm²) to AWG 8 (8.37mm²)

Flexibility: 65 bends/inch without fracture (ASTM B1/B3 tested)

Abscheider

Reinforced Interlayer Protection

Layer 1: Mylar polyester film (0.025mm) for dielectric strength

Layer 2: Aramid fiber braid (200D) for tensile reinforcement

Function: Prevents conductor migration in high-vibration environments

Nennspannung

600V AC/DC Continuous Operation

Surge Capacity: Withstands 3kV transient spikes (UL 1581 Section 900)

Key Application: Motor control panels, EV onboard chargers

Isolierung & Mantel Werkstoffe

Dual-Layer Flame Defense

Layer Material Certification
Insulation Cross-linked polyolefin (XLPO) UL 758 QPLJ8.E12345
Jacket Halogen-free thermoplastic elastomer (TPE) IEC 60754-1 (pH >6.0)
Performance Self-extinguishing in 3s (UL VW-1) Smoke density <15% (IEC 61034-2)

Widerstandseigenschaften

Engineered to Endure

Challenge Performance Test Standard
Abrasion 30,000+ cycles (1kg load) EN 50396
Chemicals Resists oil/IPA/diesel (72h immersion) ISO 1817
Heat Aging 7-day @ 136°C with <20% conductivity loss UL 1581 Sec. 470
Flame Vertical flame spread ≤50mm IEC 60332-1-2

Temperaturbereich

-40°C to +105°C Operational

Cold Flexibility: No cracking at -55°C (MIL-W-16878/4)

Heat Resistance: 30-minute survival @ 150°C (short-circuit conditions)

Verwandte Produkte

UL4348 Halogen-Free Wires

UL4348 Specifications Sheet   Pitch (mm) Conductor Insulation Resistance  At 20C Ω/km   Dielectric Strength (Vac,1min) Size (AWG) Construction (No/mm) Dia. (mm) (No.) Thickness (mm) O.D (mm)        

Kundenspezifische Kabelbaumlösungen

Kundenspezifische Lösungen für Kabelbäume - Tabelle der Kabelspezifikationen Leiter Isolierung Maximaler Widerstand (Ω/km, 20°C) Durchschlagfestigkeit (VAC, 1min) Größe (AWG): Kundenspezifisch (40-4/0) Material: Silikon, PVC, TPE, XLPE,

Kfz-Standard-Kabelbaum

Automobil-Standard-Kabelbaum Spezifikationen Leiter Isolierung Maximaler Widerstand (Ω/km, 20°C) Durchschlagsfestigkeit (VAC, 1min) Größe (AWG): 8-20 Material: XLPE Konstruktion: Dicke: 0,6-1,0mm 133/0,3mm (8AWG) Außendurchmesser: 4,5-8,2mm ≤2,1 (8AWG)

EIN ANGEBOT ANFORDERN

Füllen Sie das nachstehende Formular aus und erläutern Sie kurz Ihre geschäftlichen Anforderungen. So können wir Ihre Angebotsanfrage an das zuständige Teammitglied weiterleiten.